Seaward Apollo 600 - Seaward's all new Risk Based PAT Tester

 

Apollo 600 - A new era in risk-based portable appliance testing and health & safety management

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Apollo 600 revolutionises safety management.


With built-in risk assessment tools for any workplace hazard and a variety of
testing and inspection reports including portable appliance testing, fire detection and emergency lighting; Apollo 600 offers an all-in-one solution to managing a risk-based approach to health and safety in any workplace, reducing the burden and ensuring compliance.


Keep comprehensive client records including test and inspection reports, risk
assessments and visual evidence with the help of Seaward’s PATGuard 3 Health and Safety Edition software.

 

Key Features
High definition colour display
On board colour camera with flash
Store 2000 images
Store 50,000 appliance records
Remote data transfer from field to office
Bluetooth and USB connectivity
Built in universal and electrical risk assessment tools
Additional health & safety certificates with ability to update with more

Electrical Test Functions
Low current earth continuity test guaranteeing accurate measurement
Insulation resistance
IEC lead test
Protective conductor current
Touch current
Load power/current
Alternative leakage current
Point to point testing for fixed appliances
RCD test
Power socket test

Apollo 600 Users
Dutyholders
Health and Safety Managers
Health & Safety Contractors
Professional PAT Testers
Electrical Contractors
Facilities Managers
Risk Assessment Professionals
Operations Managers

 

1. Risk-based PAT testing


Apollo 600 follows in the footsteps of Seaward’s long line of trusted PAT testers, offering a comprehensive suite of fast and accurate electrical safety tests to enable any workplace appliance to be ested, including 3 phase equipment and residual current devices (RCDs). Apollo 600 also enables point to point testing of fixed appliances as required by the 4th edition of the IET Code of Practice for In-Service Inspection and Testing of Electrical Equipment.


In addition to its electrical test features, Apollo 600 has a built
in electrical risk assessment tool which can be used to easily
determine a risk-based suggested retest period as required by
the IET 4th Edition Code of Practice for In-service Inspection
and Testing.

 

2. Visual evidence for full traceability


Apollo 600 has a built-in digital camera enabling images taken
during visual inspections and risk assessments to be tagged
against records in PATGuard 3 software as evidence - making for
the most comprehensive and traceable record-keeping system
on the market today.

 

3. Total health and safety management


Apollo 600 features a built-in universal risk assessment tool allowing hazards to be recorded, risk scores to be calculated and corrective actions to be planned and documented easily.

 

For those who have responsibility for health and safety inspections outside of portable appliance testing, Apollo 600 also hosts a range of onboard reports for fire detection and emergency lighting, and it’s upgradeable to include more - making it an all-in-one solution for the future of health and safety management.

 

4. Superb software for total traceability


Apollo 600 has a large internal memory capable of storing 50,000 records and an additional 2,000 images. Its compatibility with Seaward’s PATGuard 3 Health and Safety Edition software means that complete test records including images can be easily managed on a PC.


Easily transfer data to a PC remotely using Apollo 600's Bluetooth function and a compatible mobile phone or tablet; or download results onto a USB flash drive. Alternatively, transfer data directly to
PC via Bluetooth or USB when back at the office. Once downloaded
to PATGuard 3, it is easy to keep track of the history of test and inspection and produce reports, certificates and invoices – offering
total peace of mind and quicker, easier management of scheduling
inspections and tests.

 

5. Greater efficiency through useful accessories
As with many Seaward PAT testers, Apollo 600 is compatible with a range of
printers and barcode scanners, further speeding up the process of asset recognition
and labelling.
Save time by uploading previously tested asset details into Apollo 600 using
PATGuard 3 software - then simply scan the barcodes of assets as you go, Apollo 600
will automatically select the required test sequence appropriate to the scanned asset.

 

 

Trade Price

£1485.00

Calibration

£70.00

 

 

 

Right Click and select Zoom and then select full screen to view larger video.....

 

 

 

Earth Continuity
Test Current ± 200mA
Display Range 0.00 MΩ – 19.99Ω
Pass Value User Defined
Insulation Resistance
Test Voltage 500V / 250V DC @ 1mA nominal
Display Range 0.01MΩ - 19.99MΩ
Pass Value User Defined
IEC Lead Test
Tests Performed Earth, Insulation Resistance, Live & Neutral Continuity
Protective Conductor Current/Load
Test Voltage Supply voltage, maximum load current 16A
Display Ranges 0.01mA – 19.99mA
Pass Value User Defined
Touch Current
Test Voltage Supply voltage, maximum load current 16A
Display Ranges 0.00mA – 3.5mA
0.00kVA – 4.00kVA
0.00A – 16.00A
Pass Value User Defined
Load Power/Current
Test Voltage 230V +10%, -15%, maximum load current 16A
Test Duration Programmable up to a maximum of 255s depending on load, i.e max duration is reduced for higher loads.
Display Range 0.00kVA – 4.00kVA
0.00A – 16.00A
Alternative Leakage Current
Test Voltage >25Vac <50Vac
Display Range 0.00mA - 19.99mA
Pass Value User Defined
RCD Trip Time
Test Voltage 230V +10%, -15%
Test Current 15mA/ 30mA rms,sinusoidal
Display Range 0ms - 2000ms
Test Method Internal isolation to avoid tripping distribution board RCD
Power Socket Test
Voltage Range 207V – 253Vac
Voltage Indicators

Line potential phase to earth

Line potential phase to neutral

Line potential neutral

General
Memory size 50,000 records & 2000 photo's
Weight 1.5kg
Dimensions 230mm x 150mm x 100mm
Power Source Mains or rechargable battery pack
Warraney 2 years (Subject to registration)