FLIR E96 Thermal Imaging Camera 24° Lens
FLIR 90202-0101
FLIR E96 Thermal Imaging Camera 24° Lens
The FLIR E96 24° Lens offers complete image coverage of near and distant target objects through a range of easily interchangeable AutoCal™ lenses. Each lens option offers fields of view for everything from:
- Wide-angle roof inspections
- Electrical inspections
Enabling the user to perform thermal imaging from a safe distance. The 640 x 480 (307,200 pixels) thermal resolution produces crisp and vibrant imagery that is enhanced with the FLIR patented MSX® technology. MSX® adds greater detail outlining the edges of the image for added detail and perspective.
The FLIR E96 24° Lens includes an optional temperature range of up to 1000°C (1832°F). With the added laser-assisted autofocus and 3 area measurement boxes, the E96 offers fantastic capability. FLIR’s onboard Inspection Route will run a pre-planned route to help you stay organised when surveying large or multiple locations. FLIR’s new thermal software, FLIR Ignite, provides the automatic uploading of all images directly from the camera to the cloud for easy, secure storage and sharing.
-
INTERCHANGEABLE, AUTO-CALIBRATING LENSES
Telephoto, standard, and wide angle AutoCal™ lenses help users survey large targets quickly, inspect electrical systems safely, or check machines for signs of failure.
-
IMPROVED CONTRAST FOR FASTER DIAGNOSIS
Use FLIR 1-Touch Level/Span to instantly improve image contrast and highlight potential electrical or mechanical issues.
-
STREAMLINED REPORTING
Onboard integration with FLIR routing software*, automatic image upload directly to the FLIR Ignite cloud library, a built-in mic for voice annotation, and report generation features all help the E76 streamline your workday. (*Optional accessory software).
FLIR REWARDS
*Spend £1,000 or more on FLIR products and get rewarded with your choice of some valuable complimentary products!
How to redeem
Download the redemption form from the download section of this page and complete your details.
Offer Valid from July 1 – September 30, 2022. Valid in the EU and UK only.
Specifications
FLIR E96 | FLIR E96 - Multiple Lens Selection |
---|---|
Specifications | |
IR Resolution | 640 × 480 pixels |
Resolution with UltraMax® enhancement | 1.2M Pixels |
Thermal Sensitivity | 42° <30 mK / 24° <40 mK / 14° <50 mK at 30°C (86°F) |
Accuracy | ±2°C (±3.6°F) or ±2% of the reading |
Digital Camera | 5 MP, with built-in LED photo/video lamp |
Display | 4", 640 × 480 pixel touchscreen LCD with auto-rotation |
Storage Media | Removable SD card |
Lens Option | |
14° Lens (Telephoto), 24° Lens & 42° Lens | Lens to be specified on order or can be ordered in multiple combinations |
Imaging & Optical | |
Color Palettes | Iron, Rainbow, Rainbow HC, White hot, Black hot, Arctic, Lava |
Detector Type and Pitch | Uncooled microbolometer, 12 µm |
Digital Camera | 5 MP, with built-in LED photo/video lamp |
Digital Zoom | 1-8× continuous |
f-number | 1.3 |
Focus | Continuous LDM, One-shot LDM, One-shot contrast, Manual |
Image Frequency | 30 Hz |
IR Resolution | 640 × 480 pixels |
Lens Identification | Automatic |
Minimum Focus Distance | 0.15 m |
Non-radiometric IR video streaming | H.264 or MPEG-4 over Wi-Fi MJPEG over UVC or Wi-Fi |
Picture-in-Picture | Resizable and movable |
Radiometric IR video recording | Real-time radiometric recording (.csq) |
Radiometric IR video streaming | Yes, over UVC |
Spectral Range | 7.5-14 µm |
Thermal Sensitivity/NETD | 42° <30 mK / 24° <40 mK / 14° <50 mK at 30°C (86°F)) |
UltraMax | Yes |
Viewfinder | No |
Measurement & Analysis | |
Accuracy | ±2°C (±3.6°F) or ±2% of the reading |
Measurement Presets | No measurement, center spot, hot spot, cold spot, User Preset 1, User Preset 2 |
Object Temperature Range | -20 to 120°C (-4 to 248°F); 0 to 650°C (32 to 1202°F); 300 to 1500°C (572 to 2732°F) |
Spot Meter | 3 in live mode |
User Interface | |
Display | 4", 640 × 480 pixel touchscreen LCD with auto-rotation |
Text | Predefined list or touchscreen keyboard |
Voice | 60 sec. recording added to still images or video via built-in mic (has speaker) or via Bluetooth® |
Power | |
Battery Operating Time | >2.5 hours at 25°C (68°F) and typical use |
Battery Type | Rechargeable Li-ion battery |
Environmental & Certifications | |
Operating Temperature Range | -15 to 50°C (5 to 122°F) |
Safety | EN/UL/CSA/PSE 60950-1 |
Storage Temperature Range | 40 to 70°C (-40 to 158°F) |
General | |
Laser Pointer | Yes |
Packaging | Infrared camera with lens, small viewfinder eyecup, 2 batteries, battery charger, hard transport case, lanyards, front lens cap, power supplies, printed documentation, SD card (8 GB), cables (USB 2.0 A to USB Type-C, USB Type-C to HDMI, USB Type-C to USB Type-C), License card: FLIR Thermal Studio Starter |